1- Internal Use Standard IM Panels
Dimensions of the panel : 4000 x 1200 mm
Thickness of the panel : 20 mm
Thickness of the external aluminum foil : 60 microns embossed
Thickness of the internal aluminum foil : 60 microns embossed
Density of the foam : 45 kg/m3
Weight of the panel : 1,40 kg/m²
Aluminum finishing : embossed / embossed
The external aluminum foil is lacquered with a weatherproof and ultraviolet rays protecting epoxy varnish.
Insulating Characteristics
Insulating material : Close cell rigid expanded pir foam, without CFC and HCFC. Material physiologically and chemically inert, insoluble.
Thermal Conductivity: 0,0216 W/mK
Foam density: 45 Kg/m3
The aluminum foils covering the panel assure a perfect vapor barrier.
Pressure Of Use
The air ducts fabricated with IM PIR 60/60 panels can be used in installations with pressures up to 1750 Pa, always in accordance with the construction standards fixed by IM.
Temperature Of Use
The air ducts fabricated with IM 60/60 panels can be used in installations with temperatures ranging from -35°C to +110°C, always operating. No relevant reduction of the insulating, chemical or physical characteristics of the panel will be observed.
Handling Warning
During all handling processes, wear gloves
Specification Of Use
The air ducts fabricated by using IM panels can be installed in plants:
- with air speed up to 35 m/s
- with pressures up to 1750 Pa
- indoor and/or outdoor
IM 60/60 panels are particularly fit for the construction of air ducts to be installed in:
- Hospitals
- Surgical Rooms
- Clean Rooms
- Pharmaceutical Industries
- Food industries
2- External Use
IM PIR PANEL 200/80
Technical Characteristics
Dimensions of the panel : 4000 x 1200 mm
Thickness of the panel : 30 mm
Thickness of the external aluminum foil : 200 microns embossed
Thickness of the internal aluminum foil : 80 microns
Density of the foam : 48 kg/m3
Weight of the panel : 2,20 kg/m²
aluminum finishing : imposed / imposed
The external aluminum foil is lacquered with weatherproof and ultraviolet rays protecting epoxy varnish.
Insulating Characteristics
Insulating material: Close cell rigid expanded pir foam, without CFC and HCFC
Thermal Conductivity: 0,0220 W/mK
Foam density: 48 Kg/m3
Temperature Of Use
The air ducts fabricated with IM panels can be used in installations with temperatures ranging from -35°C to +110°C, always operating. No relevant reduction of the insulating, chemical or physical characteristics of the panel will be observed.
Pressure Of Use
The air ducts fabricated with our panels can be used in installations with pressures up to 1750 Pa, always in accordance with the standard construction.
Handling Warning
During all handling processes, wear gloves.
Specification Of Use
The air ducts fabricated by using IM panels can be installed in plants:
- with air speed up to 35 m/s
- with pressures up to 1750 Pa
- indoor or outdoor
IM panels are particularly fit for the construction of air ducts to be installed in:
- Hospitals
- Surgical Rooms
- Clean Rooms
- Pharmaceutical Industries
- Food industries
The particular strength of the panel makes it particularly fit for the fabrication of ducts with large sections.
TECHNICAL TESTS
Characteristic | Standard Result |
Panel Stiffness / Rigidity | EN 13403 353.000 N•mm |
Resistance to high pressure | EN 13403 |
Resistance to positive/negative pressure | IM +3800 Pa / -4200 Pa No breakages or loss of functionality |
Air leakage (Positive/Negative Pressure) | EN 1507 Class “C” and “B” |
Air pressure drop inside ductwork | Negligible |
Resistance to high temperature | IM 110 °C |
Resistance to salty wither | No corrosion |
Sound reduction index | EN-ISO 140-3 Rw = 16 dB |
Thermal Conductivity | IEEE STD 442 0,02475W/(m•K) |
Thermal Resistance | IEEE STD 442-1981 |
Water absorption | ASTM D 2842-01 0.57 |
Flammability (B.S) | BS 476, Part 6 & Part 7 Class 0 |
Flammability (EU ) | EU Class B |